Pneumatic butterfly valve is composed of pneumatic actuator and butterfly valve. The pneumatic butterfly valve uses a circular butterfly plate that rotates with the valve stem for opening and closing. The pneumatic valve that realizes the activation action is mainly used as a cut-off valve. It can also be designed to have the function of adjustment or segment valve and adjustment. At present, the butterfly valve is at low pressure and large The use of medium-diameter pipes is increasing.


1. Test steps of pneumatic butterfly valve housing
 

Use the anti-rust liquid at a temperature not exceeding 38 degrees to test on the butterfly valve hydraulic test platform; the shell test pressure is 1.5 times the maximum allowable working pressure of the butterfly valve at 20 degrees; the pressure holding time is N50-DN150 60s; DN200 120s DN250-DN300 180s DN350- DN500 300s; Close both ends of the butterfly valve, the valve is partially opened, fill the valve housing with test medium, drain the air in the valve body cavity, and gradually increase the pressure to the specified test pressure, and keep the test pressure under the specified time Change, and then check the conditions of the valve housing; the test results require: there should be no structural damage, and no visible leakage is allowed.
 

2. No-load operation test of pneumatic butterfly valve

The drive device is installed on the butterfly valve, and the valve is operated from fully closed to fully open and then fully closed to open and close the butterfly valve 3 times to check whether the butterfly valve is operating normally;

Test structure requirements: the butterfly valve can be opened and closed steadily, without jamming, and can meet the sealing requirements.

3. Seal test of pneumatic butterfly valve

Use the anti-rust fluid at a temperature not exceeding 38 degrees to test on the butterfly valve hydraulic test platform; the sealing test pressure is 1.1 times the maximum allowable working pressure of the butterfly valve at 20 degrees; the pressure holding time is N50-DN500 60s; one end of the butterfly valve is closed, Close the valve opening and closing parts, fill the valve cavity with test medium, and gradually increase the pressure to the specified test pressure, keep the test pressure unchanged within the specified time, check the leakage at the other end, and then repeat the above steps and actions to turn the valve Change direction test; test result requirements: there should be no structural damage, and no visible leakage is allowed. 

Copyright! 2021 Tianjin Jiangrui Fluid Equipement Co.,Ltd.All Rights Reserved. Powered by WILLIAM

IPv6 network supported

IPv6 network supported Google Anylitics Console

contact

Send A Message

Send A Message

    If you are interested in our valves and want to know more details,please leave a message here,we will reply you as soon as we can.

  • supplier
  • contact
  • email